FAQ ¢x Sitmap¢x Contact¢x About ¡@
 
 
¡@
     
     

Description

 

Features

• Universal Full range AC input
• Installed on DIN Rail TS35/7.5 or 15
• Short circuit, Overload and Over Voltage protection
• Isolation Class II (C-DR-30/60/100-xx)
• UL 508 listed (C-DR-45xx)
• UL/CUL/TUV/CB/CE Approval
• No load power consumption <1W (C-DR-100-xx)
• LED indicator for power on
• Cooling by free air convection
• 100% full load burn-in test
• 3 years warranty


Specifications


AC input voltage range 88~264VAC; 124~370VDC
AC inrush current (Cold start) 30A at 115VAC
45A at 230VAC
DC adjustment range
(rated output Voltage)
12V: 12~15V
15V: 15~18V
24V: 24~29V
Overload protection (constant
current limiting, auto-recovery)
105~135%
Over Voltage protection
(rated output Voltage)
125~155%
Setup, rise, hold up time
(at full load and 230VAC)
2700ms, 80ms, 50ms
Withstand voltage I/P-O/P: 3KVAC
Working Temperature -20~60¢XC
(refer to output derating curve)
Safety standards UL60950-1
TUV EN60950-1 approved
EMS standards EN55022 classB, ENV50204, EN61000-3-2,3, EN61000-6-2
EN61000-4-2,3,4,5,6,8,11, EN61204-3(except CP-DR-045xx)
Connection I/P: 2 poles
O/P: 4 poles
screw DIN terminal
Packing
0.35Kg
36pcs/13.6Kg/1.1CUFT

Model


Model No.
Output Tol. R&N Effi.
Power Voltage Current
C-DR-100-12 100W 12V 0~7.5A ¡Ó1% 120mV 87%
C-DR-100-24 100W 24V 0~4.2A ¡Ó1% 150mV 89%


  Copyright © 2005 JAHT Technologies Corp. All Rights Reserved